Modeltrainsuk.com ![]()
Model Railway Accessories –
INSTALLATION & COMPONENT HANDLING WARNING
WARNING
- PLEASE READ THIS SECTION IMMEDIATELY BEFORE OPENING ANY COMPONENT PACKET
PLEASE GO TO THE RELEVANT WEBSITES BEFORE PROCEEDING
FURTHER
www.cravenmodels.com/TRAINTRONICSDCCINS.htm for TRAINTRONICS items
www.cravenmodels.com/DDCCONCEPTS.htm for DCC CONCEPTS
components
www.cravenmodels.com/PRODIGY.htm
for Prodigy DCC Systems
www.cravenmodels.com/Z21ROCO.htm
for ROCO DCC Systems
www.cravenmodels.com/ECKONBERKOINS.htm for Berko - Eckon Signals
www.cravenmodels.com/DAPOLSIGNALS.htm
for Dapol Signals
www.cravenmodels.com/TRAINTECH.htm Signals and Accessories
www.cravenmodels.com/SEEP.htm for Point Motors and electrical equipment
www.cravenmodels.com/MODELWIRE.htm
Use the correct wire for the job
www.cravenmodels.com/HELP.htm General HELP index
WARNING DELICATE ELECTRICS / ELECTRONICS
Beware of STATIC ELECTRICITY on HANDS & TOOLS
HANDLE ALL ITEMS WITH EXTREME CARE
DCC, ELECTRICAL and ELECTRONIC COMPONENT HANDLING
These COMPONENTS
contain delicate electrics / electronic components. Please read the
installation instructions very carefully – Several times.
If in any doubt
please contact your Local Electronics Expert.
Ensure that you
use the correct power supply.
Incorrect
installation will cause instant failure and possible short-circuiting.
DELICATE AND THIN WIRES
SOME WIRES ARE
VERY DELICATE AND ARE FINE BEING COATED WITH INSULATION THAT WILL CRACK AND
FRACTURE IF BENT, TWISTED OR MISHANDLED IN ANY WAY - THIS WILL CAUSE A SHORT
CIRCUIT & PERMANENT DAMAGE TO THE PRODUCT AND OTHER ITEMS WITHIN THE
CIRCUIT. ANY COILED WIRES MUST BE UNCOILED VERY CAREFULLY BEFORE INSTALLATION
TO AVOID DAMEGE TO THE INSULATION – PULLING WILL CAUSE TWISTING AND FRACUTUE.
DO NOT USE ANY METAL OBJECT TO UNCOIL THE FINE WIRES!!!!
www.cravenmodels.com/WIREHANDLING.htm
STATIC ELECTRICITY
Static
electricity refers to the build up of electric charge on the surface of
objects. The static charges remain on an object until they either bleed off to
ground or are quickly neutralized by a discharge.
Although charge
exchange can happen whenever any two surfaces come into contact and separate, a
static charge will only remain when at least one of the surfaces has a high
resistance to electrical flow (an electrical insulator).
The effects of
static electricity are familiar to most people because we can see, feel and
even hear the spark as the excess charge is neutralized when brought close to a
large electrical conductor (for example a path to ground), or a region with an
excess charge of the opposite polarity (positive or negative). The familiar
phenomenon of a static 'shock' is caused by the neutralization of charge.
Static
electricity can reside in people, clothing or tools etc.
The static
electricity must be discharged to EARTH before handling any delicate electronic
components or computer components.
Use of Magnetic
tools OR METAL OBJECTS should be avoided at all times.
Warranty and
Returns www.cravenmodels.com/TERMS.htm
CIRCUIT BOARD HANDLING
HANDLING CIRCUIT
BOARDS – DO NOT TOUCH THE UPPER OR LOWER FACES OF A CIRCUIT BOARD – FINGERS AND
TOOLS CONTAIN STATIC ELECTRICITY WHICH WILL BLOW THE COMPONENTS AND THEY WILL
NOT WORK.
HOLD BY THE OUTER
EDGES AWAY FROM ANY ELECTRONIC COMPONENTS.
A CLEAN
ENVIRONMENT IS REQUIRED.
THE LAYOUT - WIRE COLOUR CODING
Before commencing any
wiring you must decide on a wiring colour code for your layout
If you do not you will
get into a right mess !!! DON’T MIX
COLOURS across the layout !!
www.modeltrainsuk.co.uk << eShop


MODELTRAINSUK
MODEL RAILWAY
There are many different
power supplies available within the Model Industry.
Please read all the manufacturers
instructions before attempting to connect any power supply to an electrical
device.
Using an incorrect power
supply may damage the product – It may work initially but may burn out due to
incorrect voltage or amperage being used.
There are supplies that
are DC or AC. The correct one must
be used.
Some products call for
the use of Diodes and or Resistors and or
Regulators and or Controllers.
THE CORRECT SUPPLY MUST
BE USED AT
For further information please email or
telephone 01588 660580 or goto
www.modeltrainsuk.com
www.cravenmodels.com/HELP.htm << Click
|
Facilities & Services
- Please click on box required |
|
Every endeavour has been
made to ensure that the information and details contained in this file, were
accurate at the time of publication. I have a policy of constantly updating the
websites due to changing technologies and the introduction of new products etc.
The aim is to ensure that customers are kept up to date and to ensure that
Model Railway Help Guides and Technical/Educational Manuals are kept up to date
and that they are as informative as possible. It is the responsibility of every
customer to ensure that they have the knowledge and skills necessary to install
any component before making a purchase and before commencing any
installation. I sell a range of books
on the subject of Model Railways. If in
doubt ask “first” and seek advice.
Health & Safety rules must be observed at all times and children
must be supervised at all times. I make
every effort to ensure that the information on the website is accurate and up
to date. I will promptly correct any errors brought to my attention. I can
accept no responsibility for information or opinions from third parties
contained within this site, or for the content of links from this site.
Manufacturers product photographs are for illustration, products may differ
from those shown. If in doubt please telephone or email me, I will be pleased
to advise. Manufacturers specifications and product descriptions are for
guidance. Errors and Omissions accepted. I reserve the right to withdraw any
item from sale, at any point prior to dispatch, for whatever reason.
Manufacturers Warranty Terms
and Conditions apply. Goods damaged by the Customer in any way, including
incorrect installation and or product/component mishandling, are NOT covered by
warranty. 2012
James.S.Lyon T/A
Modeltrainsuk at Cravenmodels International Mail Order
Craven Model Centre, Bungalow Railway Workshops, Purslow
Estate, Craven Arms, Shropshire SY7 0HJ
Tel: 01588 660
580 10 am to 7 pm email
modeltrainsuk@btconnect.com
INTERNET TRADING FOR OVER 16 YEARS